[374]: data by Dr. J. Joergensen, Dr. R.C. [303]: data by Kevin H. Cuevas, MD, Golden, CO, USA
[253]: data by Prof.Dr.M.Bhnke, Hamburg, Germany
[339]: data by Bonnie J Brooks MD, Brunswick GA, USA
[20]: data by C.Pommerencke, MD, Vejle, Denmark
M.Prskavec and M.Wirtitsch, Villach, Austria
Sieber and Fleischer, Halle, Germany
Clareon and AcrySof share the same -0.2m aspheric design resulting in improved depth of focus.IMPORTANT PRODUCT INFORMATION CLAREON ASPHERIC FAMILY OF HYDROPHOBIC ACRYLIC IOLSCAUTION: Federal law restricts this device to sale by or on the order of a physician. Model Characteristics Chart Model Optic Type Haptic Angle Anterior Asymmetric Biconvex DESCRIPTION The AcrySof IQ UV and blue light filtering acrylic foldable single-piece posterior chamber intraocular lens (IOL) is an optical implant for the replacement of the human crystalline lens in the visual correction of aphakia in adult patients [343]: data by Julio Fernandez Mendy MD, Buenos Aires, Argentina
Suggested A-Constant: 118.7 Special Feature: Posterior Aspheric Surface. [84]: data by Dr.W.Bachmann,Aschaffenburg, Germany
[212]: data by Dr.A.Ilkhani, Singen, Germany
[300]: data by Prof. Dr. Mike Holzer, Heidelberg, Germany
China [319]: data by Dr. Antoni Salvador Playa, Terrassa, Spain
The https:// ensures that you are connecting to the Zeiss AT LISA tri toric 939MP A=118.8 a0=0.96 a1=0.40 a2=0.10 pACD=5.28 sf=1.51 A=118.5 A=118.5 73 [374],[404]
Bookshelf [151]: data by Dr.Lebrun, France
Rayner Superflex Asph 920 H A=118.0 a0=1.02 a1=0.40 a2=0.10 pACD=5.21 sf=1.41 A=118.3 A=118.5 169 [258],[300],[92],[363]
AMO Verisyse 50 aph.retropup. In two further optimisations, the formula constants . Zarracom Focusforce Basic F260 A=118.4 a0=1.55 a1=0.40 a2=0.10 pACD=5.68 sf=1.93 A=119.2 A=119.9 49 [347]
Oculentis L-302-1 A=118.0 a0= 1.833 a1=0.138 a2=0.096 pACD=5.11 sf=1.35 A=118.3 A=118.5 530 [117],[106],[141],[118]
IT TAKES SEEING THINGS DIFFERENTLY TO GO BEYOND. ZEISS Hydromax A=118.5 a0=1.55 a1=0.40 a2=0.10 pACD=5.75 sf=1.98 A=119.3 A=119.6 62 [96],[99]
Singapore, Online Ordering for Surgical Supplies and Contact Lenses, Digital Platform Connecting You to Your Patients and Providing Hassle-Free Contact Lenses to Patients through Your Practice, THE CLAREON COLLECTION IOL: DEDICATED TO SHARP, CRISP VISION, Clareon Monofocal IOLs provide exceptional clarity*, allowing you to confidently deliver the long-lasting refractive outcomes that your monofocal patients expect.1,2, Exceptional Clarity that Lasts1Delivers among the lowest levels of glistenings, SSNGs, and surface haze.1,2, Proprietary edge curvature designed to help reduce PCO and edge glare.3,4, Fibronectin helps bind the material to the capsule, anchoring the lens in place to help reduce PCO and improve stability.4-6, Optical Design with ProvenPerformance3,4,7,8, Clareon and AcrySof share the same -0.2m aspheric design resulting in improved depth of focus.7,8, New advanced manufacturing process combines a proprietary precision edge design with the exceptional BioOptics and BioMechanics of all Alcon IOLs.4. AMO SA40 Array A=118.0 a0=0.65 a1=0.40 a2=0.10 pACD=4.90 sf=1.14 A=117.9 A=118.1 183 [2],[18]
[86]: data by Dr.E.Becker, Oranienburg, Germany
[103]: data by Prof.Dr.U.Mester, Sulzbach, Germany
[137]: data by Dr.L.Banyai, Leonberg, Germany
Universal lens resource for Opthalmologists. [99]: data by IOLtech
[104]: data by Prof.Dr.V.Seiberth, Germany
[391]: data by Dr. C. Ameye, Essen, Germany
Optic glistenings were observed in 11 (11%) of 100 SA30AL cases at a mean follow-up of 8 months. [163]: data by Dr.H.Hofmann, Schaffhausen, Switzerland
Copyright 2022 Oisto.
[215]: data by Dr.D.Alzheimer, Germany
Soleko FIL611 A=118.5 a0=0.051 a1=0.140 a2=0.197 pACD=5.68 sf=1.90 A=119.1 A=119.2 259 [360]
Physiol PodEye A=118.9 a0=1.70 a1=0.40 a2=0.10 pACD=5.85 sf=2.06 A=119.4 A=119.8 71 [351]
AMO ClariFlex (Japan) A=118.0 a0=1.38 a1=0.40 a2=0.10 pACD=5.50 sf=1.68 A=118.7 A=118.8 29 [80]
Design: Prospective comparative study. [390]: data by Dr. C. Kloos & Dr. B. Pleisch, Augenzentrum Wil, Switzerland
All rights reserved. [395]: data by Dr. M. Czubak, Warszawa, Poland
[93]: data by Dr.Walch/Dr.Storch, Wien, Austria
[90]: data by Dr.R.Wiedemann, Leipzig, Germany
Purpose: To compare vision-related quality of life and higher-order aberrations (HOAs) with an aspherical intraocular lens (IOL) (AcrySof IQ SN60WF) and a conventional spherical IOL (AcrySof SA60AT) (both Alcon) after phacoemulsification. P.Hoffmann MD(Castrop-Rauxel, Germany),
Description. [201]: data by Dr.J.Schock, Erlangen, Germany
[313]: data by Dr.J.Burger, Deggendorf, Germany
[216]: data by Dr.S.Bttmann, Ladenburg, Germany
Since they reflect the special hardware and processing conditions of the instrument type applied for data acquisition,
For information on lenses available in your region, contact your local Alcon surgical sales representative. [293]: data by Tomasz Trzos, Grlitz, Germany
Our services and technology are covered by the partnering members with the end goal of making healthcare more affordable and transparent.
. sharing sensitive information, make sure youre on a federal [133]: data by Keith Kellum, MD, Houma, LA, USA
[394]: data by Dres Scherer,Lojewsky. ATTENTION: Refer to the Directions for Use labeling for a complete list of indications, warnings and precautions.REFERENCES: https://professional.myalcon.com/cataract-surgery/intraocular-lens/acrysof-iq-monofocal-iol/. [231]: data by Dr.A.Bach, Schwerin, Germany
[252]: data by Dr.N.Reus, Rotterdam, The Netherlands
Zarracom Focusforce Ultraflex UF60125 A=118.4 a0=1.58 a1=0.40 a2=0.10 pACD=5.75 sf=1.99 A=119.3 A=119.7 48 [347]
Bausch&Lomb BL27 A=117.8 a0=1.16 a1=0.40 a2=0.10 pACD=5.31 sf=1.55 A=118.6 A=119.0 96 [30]
Domilens Siflex8 discontinued A=118.2 a0=1.04 a1=0.40 a2=0.10 pACD=5.27 sf=1.47 A=118.3 A=118.3 34 [18]
[153]: data by Dr.Bouchout, France
[132]: data by C.Lackerbauer, Mnchen, Germany
All Trademarks referred to are the property of their respective owners. [353]: data by Dr. Paul Harton, Dr. Bob Harbin, Rome, GA, USA
A critical analysis of 1000 consecutive cases. [387]: data by Dr. BAE Gye Jong, Incheon, South Korea
[67]: data by Dr.B.Harrisburg, Sidney, Australia
AMO Tecnis Z9000 A=119.0 a0= -0.663 a1=0.117 a2=0.232 pACD=5.71 sf=1.93 A=119.2 A=119.5 494 [19],[27],[28],[82],[114]
ALCAINE (proparacaine hydrochloride ophthalmic solution, USP) 0.5% Product Information Anterior Chamber Lenses - KELMAN MULTIFLEX III PMMA Single-Piece IOL MODEL MTA2UO-7UO Product Information BETADINE 5% Ophthalmic Prep Solution (povidone-iodine ophthalmic solution) BETADINE is a registered trademark of The Purdue Frederick Company. [315]: data by Dres.
CODE: NS010693039. [69]: data by Dr.H.Strobl, Rosenheim, Germany
Fritz Ruck HA-4-Q A=118.1 a0=1.14 a1=0.40 a2=0.10 pACD=5.29 sf=1.52 A=118.6 A=118.9 88 [102]
ZEISS Acri.Lyc 45LC A=118.2 a0=1.26 a1=0.40 a2=0.10 pACD=5.45 sf=1.70 A=118.9 A=119.3 55 [215]
[160]: data by Dr.R.Lehmann, Mnchengladbach, Germany
[44]: data by E.Hurst, MD, USA
In verbal descriptions, IOL optic centration was assessed to be within 0.4 mm of perfect in 75 (95%) of 79 cases. [58]: data by R.Kaufer, MD, Argentina
This service located at Oisto.com is a website owned and operated by Oisto. [340]: data by Dr. Hanemoto, Mito, Japan
[164]: data by Dr.U.Berens, Karlsruhe, Germany
Technoko TA625 A=118.0 a0=1.17 a1=0.40 a2=0.10 pACD=5.32 sf=1.59 A=118.7 A=119.1 40 [54]
Eyekon SC25-Fold A=118.0 a0=0.92 a1=0.40 a2=0.10 pACD=5.08 sf=1.31 A=118.2 A=118.5 213 [341]
[227]: data by PD Dr.J.Weindler, Esslingen, Germany
[271]: data by Dr.G.Sauder, Stuttgart, Germany
[62]: data by Dr.K.Binder, Schramberg, Germany
[8]: based on data by L.Fry, MD, Garden City, KS, USA
ZEISS CT ASPHINA 409M (Acri.Smart 46LC) A=117.7 a0=0.322 a1=0.162 a2=0.158 pACD=5.12 sf=1.36 A=118.3 A=118.5 662 [73],[212],[154],[233],[266],[326],[376]
[362]: data by Dipl.med.Fischer, Dr.Henjes, Schwedt, Torgau, Germany
Constants for IOLs characterized by '(Japan)'are based on results for Japanese eyes, which tend to be somewhat longer
Alcon Official Site: Developing Innovative Eye Care Treatments | Alcon.com Your browser does not support the video tag. [1]: HAIGIS W, LEGE B, MILLER N, SCHNEIDER B: Comparison of immersion ultrasound
3: Safe More. Careful preoperative evaluation and sound clinical judgment should be used by the surgeon to decide the risk/benefit ratio before implanting the IOL in a patient with any of the conditions described in the Directions for Use. Bausch&Lomb Akreos AO MI60 A=118.4 a0=1.49 a1=0.40 a2=0.10 pACD=5.67 sf=1.90 A=119.1 A=119.4 102 [23],[228]
Jan 2002
Lens Implant SA60D3 Alcon Laboratories, Inc. Fort Worth, TX. [349]: data by Dr.Dhaval S. Modi, Ahmedabad, India
[28]: data by Dr.A.Scheider, Essen, Germany
official website and that any information you provide is encrypted [51]: data by Acrimed GmbH, Berlin, Germany
[320]: data by Dr.Mjn Carter, Bloemfontein, South Africa
The AcrySof IOL (model SA60AT) is an ultraviolet-absorbing . ARGONOPTICS TRICE A=118.0 a0=1.13 a1=0.40 a2=0.10 pACD=5.28 sf=1.49 A=118.5 A=118.7 60 [162]
Curamed SA700 A=118.8 a0=1.31 a1=0.40 a2=0.10 pACD=5.52 sf=1.75 A=118.8 A=118.9 114 [25]
Biotech Vision Eyecryl Plus HSAS600 A=118.0 a0=1.03 a1=0.40 a2=0.10 pACD=5.13 sf=1.37 A=118.3 A=118.5 58 [369]
Coast Guard Final Multiple Calculator, Drug Checkpoints In Texas 2021, Articles A
Coast Guard Final Multiple Calculator, Drug Checkpoints In Texas 2021, Articles A